  1. P

    Wont start without unplugging capacitor

    SOLVE Replace the wiring harness and Voila. Started with cap on and has reverse Thank you everyone who help out, much appreciated....
  2. P

    Wont start without unplugging capacitor

    off the cap 6 VDC with it sorry to say, same thing, 6 VDC off the cap. waiting for a new harness
  3. P

    Wont start without unplugging capacitor

    will let you know for sure thank you, so she will run without plugged in. ok
  4. P

    Wont start without unplugging capacitor

    no kidding , lol Sounds good, Im up for anything right now. will be home tomorrow. yes we did swap the stator and flywheel. same result Thx man
  5. P

    Wont start without unplugging capacitor

    Ya Bummer man. looking for one also. thank you
  6. P

    Wont start without unplugging capacitor

    Thank you for sharing information, I hope I don't have that problem also.
  7. P

    Wont start without unplugging capacitor

    No I didn't get a hardness yet, Looking to get a new fuel pump, but I doubt if it will fix my problem since I'm cannot getting 14.6 vdc out of the Red wire off the VR even when I have the whole hardness not plugged into the RED wire. Anyone had a match I can borrow
  8. P

    Wont start without unplugging capacitor

    why would this make the pump draw more dc amps ? plugged
  9. P

    Wont start without unplugging capacitor

    Oh, IC. by the fuel pickup you mean fuel pump right, here is Canada we don't say pickup, pickup is a truck...lol
  10. P

    Wont start without unplugging capacitor

    I saw on the other post it should be around 4.3 to 4.5 amp DC anything over 5 amp DC will have problems, I didn't see anything on the Service manual how to test dc amp draw numbers so I have nothing to compare. I also ran the vin number if it did have a recall for the pump and the result negative.
  11. P

    Wont start without unplugging capacitor

    The draw I have is 5.93 to 6 Amps DC to the fuel pump. Would this be too much to cuz voltage drop to the harness and no start when cap is plugged in. No Cap is start (give and take).
  12. P

    Wont start without unplugging capacitor

    I have no clue if the recall was done on the fuel pump, will need to talk to the owner. waiting for my fuse to check the draw on the fuel pump.
  13. P

    Wont start without unplugging capacitor

    First thank you for the information above I was going to tell you the dc amp draw from the pump but my meter has a blown fuse. I soon I get a new fuse for the fluke meter I will let you know. Your problem is the red wire to the relay coming from the VR, if no 14.6 vdcs from VR you will not have...
  14. P

    Wont start without unplugging capacitor

    k, all look good, did check and cleaned connectors, I'm looking for a hardness on ebay
  15. P

    Wont start without unplugging capacitor

    yessir, new VR , new cap, new relay and swap stator and flywheel